Trupace Cardiac Pacing Wire
Pack Sizes Available
Product Description
Technical Specifications
- Brand / Manufacturer: Trupace — Sutures India Pvt Ltd (a division of Healthium Medtech)
- SKU / Model: TP 60 | Catalogue code: I14-470/TP 60
- Wire Construction: Braided stainless steel multifilament conductor, 0.3mm gauge; nylon (polyamide 6) insulation along full length except distal un-insulated electrode end
- Needle Configuration: Double-armed: curved needle at distal (myocardial fixation) end; straight breakpoint needle at proximal (external pacemaker connection) end
- Wire Length: 60cm (standard adult epicardial pacing wire length)
- Sterilization and Pack Size: Ethylene oxide (EO) sterilized; single-use only; individually sterile packed; supplied in box of 12 units
Frequently asked questions
Trupace is a temporary cardiac epicardial pacing wire manufactured by Sutures India. It is used during and after open-heart surgery to provide temporary cardiac pacing — that is, to deliver controlled electrical impulses to the heart muscle to maintain an appropriate rhythm when the heart's own conduction system may be temporarily disrupted. The wire is placed by the surgeon on the epicardial surface of the heart before chest closure and is removed once the patient's cardiac rhythm has stabilised, typically within a few days of surgery.
The Trupace pacing wire consists of a braided stainless steel multifilament conductor at 0.3mm gauge, insulated along most of its length with nylon (polyamide 6). The distal un-insulated end is crimped to a curved needle for myocardial fixation. The proximal end is attached to a straight breakpoint needle, which exits through the chest wall and connects to the external pacing device. The breakpoint needle design allows the proximal needle to be detached cleanly at the skin surface when the wire is removed, without requiring cutting instruments.
The Trupace TP 60 is 60cm in total length, which is the standard for epicardial temporary pacing wires used in adult cardiac surgery. It is supplied in a box of 12 units, with each wire individually sterile packed. This is the confirmed industry-standard pack size for cardiac pacing wires, consistent with all major brands supplying the same product category globally.
Ventricular pacing wires are placed on the diaphragmatic surface of the right ventricle and are used when ventricular rate support is needed. Atrial pacing wires are fixed to the right atrium when atrioventricular synchrony needs to be maintained post-operatively. Both placements are performed using the same type of epicardial pacing wire. The Trupace wire with its curved needle for myocardial fixation and straight exit needle is suitable for both atrial and ventricular placement at the surgeon's discretion.
Temporary epicardial pacing wires are typically removed between two and seven days post-operatively, once the patient's native cardiac rhythm has returned and the risk of needing pacing has reduced to an acceptable level. Removal involves cutting the skin-surface suture securing the wire, applying gentle, purposeful traction to withdraw the wire from the epicardial surface, and monitoring the patient for any complications. Anticoagulation levels are considered before removal due to the small but real risk of bleeding or cardiac tamponade. These are clinical decisions made by the managing surgical team.
Yes. Sara Wellness regularly exports Sutures India products including cardiac surgical consumables to buyers across Africa, the Middle East, and Southeast Asia. Full export documentation is provided, including commercial invoices, packing lists, certificates of origin, and any product compliance documentation required by the destination country. MOQs are flexible for first-time buyers or those building a combined cardiac surgical product order.
Related Products
Explore more high-quality items from our Surgical Supplies range.

3M Electrosurgical Patient Return Electrode Plate
The difference between a routine electrosurgical procedure and one with complications can come down to something as mundane as whether the return electrode maintained proper skin contact for the entire case. Nobody thinks about the grounding pad until it fails. Then suddenly everyone is thinking about it. The 3M Electrosurgical Patient Return Electrode Plate is engineered specifically to be the piece of equipment that nobody has to think about twice during surgery. This is a disposable, single-use dispersive return electrode designed to safely return electrosurgical energy from the patient's body back to the electrosurgical generator. The pad provides a large conductive surface area that disperses current over a broad contact zone, minimizing heat concentration and reducing the risk of patient burns at the electrode site. That broad dispersion is what separates a properly designed return electrode from the kind that causes thermal injuries. The conductive adhesive is water-based hydrophilic gel that flows uniformly into skin crevices and irregularities, maximizing skin-to-pad contact and ensuring reliable electrical conductivity throughout the procedure. The hydrogel formulation provides strong adhesion without leaving residue on the skin after removal, which matters considerably when dealing with friable or sensitive patient skin. The non-conductive border adhesive surrounds the conductive area to maintain electrical isolation and prevent edge burns. Split (dual foil) electrode designs are compatible with electrosurgical generators equipped with Contact Quality Monitoring Systems (CQMS), including all major monitoring platforms like REM, ARM, NESSY, and PSS. The split design allows the generator to continuously monitor pad-to-patient contact quality and alert surgical staff immediately if impedance rises or contact is compromised. This active monitoring significantly reduces the risk of alternate-site burns, which can occur when the return path is inadequate. The foam backing material is lightweight, conformable, and biocompatible, tested negative for cytotoxicity, skin sensitization, and acute cutaneous irritation. Scalloped edges improve adherence and reduce lifting at pad borders. The pad is designed for universal patient use where full skin contact and a suitable placement site can be obtained, accommodating both adult and pediatric applications depending on size selected. Clinically, these electrodes are used in any surgical procedure involving electrosurgical cutting or coagulation. Common applications include general surgery, gynecological procedures, orthopedic surgery, ENT procedures, and plastic surgery where monopolar electrosurgery is employed. For distributors supplying operating rooms, ambulatory surgery centers, and hospital surgical departments, electrosurgical return electrodes are high-turnover disposable supplies with predictable consumption rates tied directly to surgical volume. They are essential inventory for any facility performing electrosurgery. Sara Wellness has been exporting surgical consumables and operating room supplies from India for 15 years. Electrosurgical return electrodes are safety-critical devices where material quality, adhesive performance, and conductive gel composition directly impact patient outcomes. We source from manufacturers whose production standards meet international specifications for medical-grade materials and electrosurgical safety. We work one-on-one with every buyer. MOQs are flexible because we know that a distributor adding a surgical consumables line is in a different position from an established wholesaler managing regular hospital supply contracts.

Covidien Appose Disposable Skin Stapler
Wound closure after a surgical incision should be as fast and reliable as the procedure that preceded it. Placing sutures closes the wound but adds time and the potential for inconsistency. Skin stapling does the same job in less time, with consistent closure geometry that does not depend on knot tension or stitch spacing. For the long incisions of general surgery, orthopaedic surgery, and Caesarean section, the skin stapler has become a standard part of the closure routine. The Covidien Appose ULC is one of the most widely recognised disposable skin staplers in the market. The design is built around an easy-squeeze trigger that fires one staple per press, an ejector spring that automatically disengages the staple to facilitate instrument removal in any direction, and a clear view of the tissue being stapled through the transparent cartridge window. The slim body reduces the visual obstruction of the wound site during placement. Two staple sizes are available. Regular staples are 4.8mm wide with a 3.4mm leg length for standard wound closure. Wide staples are 6.5mm wide with a 4.1mm leg length for thicker skin or situations where wider tissue bridge coverage is preferred. Both are made from stainless steel. The stapler is single-use and sterile from the packaging. There is no activation step — remove from packaging, position, fire. Each unit comes pre-loaded with 35 staples, which is sufficient for the majority of surgical incision closures in a single unit. For surgical supply distributors and hospital procurement teams, Covidien Appose is a recognised brand that surgical departments request specifically. Box-of-12 purchasing is the standard institutional format. Sara Wellness exports Covidien surgical products to distributors internationally, with 15 years of experience in medical device export documentation and logistics.

Covidien Surgipro Flat Mesh — 15 x 15 cm
Hernia repair accounts for approximately 20 million procedures globally each year. That makes it one of the most common elective surgical procedures performed worldwide, and mesh-based tension-free repair has been the standard of care for most hernia types for the past three decades. The quality of the mesh implanted influences the rate of hernia recurrence, the risk of mesh-related complications, and the patient's long-term experience. Surgeons who perform hernia repair regularly develop preferences for specific mesh products, and those preferences drive procurement decisions in surgical departments. Covidien Surgipro Flat Mesh is a nonabsorbable polypropylene surgical mesh designed for both open and laparoscopic hernia repair. The polypropylene construction is permanently implanted — the body incorporates the mesh through tissue ingrowth over time, forming a permanent scaffold that reinforces the abdominal wall defect. The mesh is knitted in an open-weave structure that allows tissue ingrowth while maintaining the dimensional stability required for proper repair. The 15x15cm flat sheet format is the most commonly ordered size for inguinal hernia repair, providing sufficient material for proper overlap of the hernia defect plus anchoring margin without requiring intraoperative trimming in most standard cases. For ventral or incisional hernias where larger coverage is required, the 30x30cm format is available. Bi-directional elasticity in the mesh construction means it can be cut to any shape required without fraying or unravelling at the cut edges. This is a practical property that matters in the surgical field. For surgical supply distributors and hospital theatre managers, Surgipro is a recognised Covidien (Medtronic) brand with institutional supply credibility. Sara Wellness exports surgical mesh products internationally with complete regulatory documentation for medical device imports.