
Cannula Fixator for IV (IV Cannula Securement Dressing)
Pack Sizes Available
Product Description
Technical Specifications
- Material: Transparent polyurethane film or non-woven film with hypoallergenic acrylic adhesive
- Available Sizes: Small (paediatric), Medium (standard adult), Large (winged / large hub cannula)
- Sterility: Sterile (ETO or gamma irradiated), individually packed, single use
- Transparency: Transparent film allows continuous site inspection without dressing removal
- Adhesive: Hypoallergenic skin-friendly adhesive — secure fixation with low trauma on removal
- Compatible Devices: Peripheral IV cannulae (all gauges), over-the-needle catheters, winged infusion sets
Frequently asked questions
A cannula fixator secures the IV cannula hub, wings, and connecting tubing junction against the patient's skin to prevent accidental dislodgement, kinking, or movement of the cannula within the vein. Secure fixation reduces the risk of infiltration (fluid leaking into surrounding tissue), phlebitis (vein inflammation from cannula movement), and accidental removal during patient repositioning or activity.
Transparent polyurethane film allows nurses and clinicians to visually inspect the IV insertion site continuously for early signs of redness, swelling, infiltration, and infection without removing the dressing. Tape is opaque, requires removal for site inspection (which disrupts fixation), is more likely to cause skin damage on removal, and provides less consistent fixation. Transparent dressings also allow shower and sponge bath without the dressing becoming waterlogged.
Standard clinical guidelines recommend reviewing and replacing IV site dressings every 24-72 hours or whenever the dressing becomes wet, soiled, or loose — whichever comes first. The underlying cannula should be re-sited per your facility's peripheral IV cannula replacement protocol (typically 72-96 hours in adult patients unless complications develop sooner). The cannula fixator is replaced each time the IV site dressing is changed.
Yes. Cannula fixators are available in small (paediatric), medium (standard adult), and large (for larger cannulae or winged butterfly devices) sizes. Size selection should match the cannula gauge and hub dimensions for correct coverage and fixation. Using a fixator that is too small provides inadequate coverage; too large creates unnecessary bulk and may lift at the edges prematurely.
Yes. Cannula fixators are sterile individually packed, single-use devices. Each dressing is used once per patient per IV site. Once removed, the dressing is discarded as clinical waste. Never re-use or share dressings between patients. The sterile packaging should be inspected for integrity before use — do not use a dressing from a compromised or torn package.
Related Products
Explore more high-quality items from our IV Infusion and Transfusion range.

2 Port Manifold Right On / Right Off Stainless Steel
Simultaneous infusion of multiple medications through a single IV line sounds straightforward until someone needs to adjust flow rates mid-procedure and discovers that changing one stopcock affects pressure dynamics across the entire line. Or when debubbling one port requires disconnecting three others. These are the small operational frustrations that turn routine fluid management into a coordination exercise that nobody has time for during critical care. The 2 Port Manifold Right On / Right Off eliminates those friction points through intentional valve geometry and handle placement. This is a stainless steel two-port infusion manifold designed for simultaneous delivery of multiple medications or fluids through separate access ports during anesthesia, cardiac surgery, critical care, and interventional procedures. The right on / right off designation indicates that both rotating handles turn clockwise to open flow and counter-clockwise to close, providing consistent operational logic that reduces valve-position errors during high-pressure clinical situations. This handle orientation standardization matters because muscle memory under stress defaults to learned patterns, and mixed handle orientations across different devices introduce cognitive load that increases error risk. The stainless steel construction provides pressure resistance up to 500 psi, making the manifold suitable for power injection applications in interventional radiology and cardiac catheterization where high-pressure contrast media delivery is required. Polycarbonate-body manifolds cannot withstand these pressures and are limited to gravity-flow applications. The steel body is also autoclavable, though most manifolds are supplied sterile and intended for single-use disposal. Each port features standard Luer lock connections ensuring secure attachment to syringes, extension tubing, and infusion pumps. The transparent polycarbonate handles allow visual confirmation of valve position and internal fluid paths, enabling operators to verify flow status at a glance without relying solely on handle orientation. This visibility is particularly valuable for debubbling procedures where air must be visually tracked and expelled before connecting to patient lines. The two-port configuration is the minimum manifold size, offering fewer connection points than three-port or six-port alternatives. Fewer ports mean lower dead space volume, faster flushing, and reduced medication interaction within the manifold body. For applications requiring only two simultaneous infusions, the two-port design minimizes unused access points that could become contamination risks if left capped. The manifold's compact footprint makes it suitable for crowded procedural fields where space on the sterile drape is limited. Rotating Luer connections at each port allow extension tubing to be oriented in any direction, accommodating the ergonomic and spatial constraints of different procedural setups. For distributors supplying operating rooms, catheterization laboratories, intensive care units, and anesthesia departments, stainless steel manifolds represent durable infusion accessories with predictable consumption tied to procedural volume. Sara Wellness has been exporting IV infusion components and procedural accessories from India for 15 years.

BD Arterial Cannula with Floswitch (20G/22G — Peripheral Arterial Access)
The radial artery is not a forgiving location for inferior equipment. It sits at the wrist, smaller than a peripheral vein, and the clinical team doing the arterial line needs insertion to work on the first or second attempt. After insertion, that line stays in place for continuous blood pressure monitoring or serial arterial blood gas draws — sometimes for days. The material and design of the cannula matter from the moment of insertion to the moment of removal. BD Arterial Cannulas have been used successfully for peripheral arterial access since 1980. The catheter body is made from FEP or PUR — both fluoropolymer materials with a critical property: they remain pliable at body temperature without softening excessively, which means the catheter tracks well through tissue after the needle is withdrawn and holds its position against arterial pressure without kinking. The atraumatic needle bevel assists first-pass insertion and reduces the intimal trauma that increases the risk of postprocedural arterial occlusion. The Floswitch is the feature that distinguishes this design from basic arterial cannulas. It is an on/off valve integrated directly onto the hub that prevents blood backflow and exposure when the transducer tubing is being connected or disconnected. This matters for two reasons: air embolism risk (a Floswitch-closed hub prevents air entering an open arterial circuit) and blood exposure risk for the clinical team. The needle safety guard activates on withdrawal, covering the sharp needle bevel automatically to prevent needlestick after the cannulation is complete. The 20G size (1.1 x 45mm, red) is the most widely used for adult radial artery lines. The 22G (0.9 x 25mm, blue) is selected where arterial calibre is smaller or in patients at higher risk of occlusion — evidence from comparative trials suggests lower thrombosis rates with 22G in higher-risk populations. For critical care equipment distributors, hospital procurement offices, and ICU consumable buyers — arterial cannulas are a non-optional stock item in every ICU and theatre environment running haemodynamic monitoring. Sara Wellness exports BD arterial access products and related critical care consumables to international wholesale buyers. Fifteen years of export experience. Direct one-on-one communication on every order, flexible MOQ arrangements, and correct documentation for your import destination.