ATPL Urine Pot (Disposable Specimen Collection Container)
Lab Supplies

ATPL Urine Pot (Disposable Specimen Collection Container)

Pack Sizes Available

Available volumes: 30ml, 60ml, 80ml, 100ml, 120ml
Pack sizes: 100 units per pack

Product Description

The urine specimen container is the product that every hospital uses in genuinely enormous quantities and almost nobody ever thinks carefully about until there is a problem with one. The cap leaks in transit. The lid is too tight to open with gloved hands. The graduation markings rub off before the sample reaches the laboratory. These are small frustrations that compound quickly when you are dealing with hundreds of samples per day across a pathology department. The ATPL Urine Pot is a disposable specimen collection container manufactured from medical-grade polypropylene. Polypropylene is the right material for this application — it is chemically inert (does not react with urine or any urinalysis reagents), transparent enough for direct visual inspection of sample volume and colour, and compatible with the full temperature range of laboratory handling including refrigeration. The wide-mouth design allows comfortable collection without patient difficulty, and the screw cap provides a reliable leak-proof seal for sample transport within the hospital or to external reference laboratories. The container is available in 60ml, 80ml, and 100ml volumes — the 60ml and 80ml sizes suited to routine urinalysis and dipstick testing where a moderate sample volume is sufficient, and the 100ml size providing extra capacity for patients who require a larger collection or for samples requiring multiple tests from a single collection. Moulded-in graduation markings on the container wall allow direct volume reading without measuring cylinders or additional equipment. The non-sterile variant is appropriate for the majority of urine tests: routine urinalysis, urine microscopy, pregnancy tests, drug screening, and biochemical urine tests. Sterile variants in individually wrapped packaging are available for urine culture and sensitivity (MC&S) testing, where sample contamination would invalidate the microbiological result. For hospital supply distributors, pathology laboratory consumable buyers, and clinical supply procurement officers — urine containers are a core, non-negotiable, high-velocity line item. The consumption volume across an active pathology department is predictable and continuous. Sara Wellness exports ATPL medical consumables to wholesale buyers. Volume pricing applies on bulk orders. MOQs are flexible for both trial and established supply contracts.

Technical Specifications

  • Material: Medical-grade virgin polypropylene (PP); chemically inert; transparent for direct visual inspection; compatible with routine laboratory handling temperatures including refrigeration at 2-8°C
  • Closure: Screw cap (polyethylene or polypropylene cap); leak-proof seal for specimen transport; wide-mouth opening for comfortable and hygienic specimen collection
  • Available Volumes: 30ml | 60ml | 80ml | 100ml | 120ml; moulded-in graduation markings on container body for direct volume reading; wide-mouth design for ease of collection
  • Sterility Options: Non-sterile (routine urinalysis, microscopy, pregnancy test, drug screening, biochemical tests) | Sterile (urine culture MC&S testing, individually wrapped); sterile containers internally sterilised by gamma irradiation
  • Regulatory Compliance: Medical-grade polypropylene meeting ISO quality standards; CE marking applicable; ATPL brand manufactured to Indian Standard requirements for specimen containers; for single use only — do not reuse
FAQ

Frequently asked questions

Non-sterile urine pots are suitable for the majority of routine urine tests: urinalysis (dipstick testing for glucose, protein, blood, nitrites, leucocytes, pH, and specific gravity), urine microscopy (examining cells and casts under a microscope), urine pregnancy tests, urine drug screening, and most biochemical urine measurements (24-hour urine collections for creatinine, protein, electrolytes, etc.). For these tests, the container does not need to be internally sterile because the test method accounts for the presence of commensal organisms. Sterile urine containers — individually wrapped and internally sterilised — are required specifically for urine culture and sensitivity (MC&S) testing, where the laboratory cultures the urine to detect and identify bacterial pathogens. For MC&S, any contamination of the container introduces false organisms and invalidates the test result.

The appropriate container volume depends on the tests being ordered. For routine urinalysis (dipstick plus microscopy), 30-60ml containers are sufficient — most dipstick tests require only 10-20ml and a microscopy examination requires a similar volume after centrifugation. A 60ml or 80ml container gives adequate collection capacity without requiring the patient to produce an uncomfortably large sample. For urine culture (where a midstream clean-catch sample is required), a 60-100ml container allows collection of the first portion (discarded) and the midstream portion (captured) with space to spare. For 24-hour urine collections (for creatinine clearance, protein quantification, or electrolytes), a 2-3 litre dedicated 24-hour collection container is required rather than a standard urine pot.

ATPL is an Indian manufacturer of disposable medical and laboratory consumables supplying to hospitals, pathology laboratories, diagnostic centres, and clinical research organisations. ATPL urine specimen containers are manufactured from medical-grade virgin polypropylene meeting relevant Indian Standard and CE marking requirements for specimen containers. The containers are manufactured in compliance with ISO quality management standards. Medical-grade polypropylene is used specifically because it is certified for direct contact with biological specimens — it is chemically inert, non-reactive with urine or reagents, and free from contaminants that could interfere with laboratory analyses.

Urine specimens in sealed containers should be transported to the laboratory as promptly as possible after collection. If immediate analysis is not possible, specimens can be refrigerated at 2-8°C for up to 2 hours (for most routine urinalysis tests) or up to 24 hours for urine culture (refrigeration inhibits bacterial multiplication and preserves the viability of pathogens). At room temperature, urine begins to deteriorate rapidly: bacterial counts increase, leucocytes lyse, casts dissolve, and pH shifts. Specimens for routine urinalysis should be analysed within 2 hours of collection at room temperature, or within 4 hours if refrigerated. Always ensure the screw cap is fully tightened before transport to prevent leakage.

Standard ATPL urine pots with wide-mouth openings are suitable for paediatric specimen collection from children who can cooperate with a midstream collection. For infants and neonates who cannot cooperate with midstream collection, a standard urine pot alone is insufficient — paediatric urine collection bags (adhesive bags applied to the perineal area) are typically used to collect the specimen first, with the collected urine then transferred to a urine pot for transport to the laboratory. The sterile urine pot variant is recommended for paediatric urine culture samples to prevent contamination, which is especially important in paediatric populations where urinary tract infections are a common diagnostic consideration.

ATPL urine pots are supplied in packs of 100 units per pack for standard clinical supply use. Bulk institutional packs of 500 or 1000 units are available for high-volume pathology departments and hospital wards with high specimen throughput. Non-sterile containers are typically packed in bulk poly bags within the master carton. Sterile variants are individually wrapped in peel-away pouches and packed in cartons. For export orders, Sara Wellness can supply in full carton quantities with export documentation, applicable regulatory compliance certificates, and cold-chain or standard freight arrangements depending on the destination country's import requirements for medical consumables.

You might also like

Related Products

Explore more high-quality items from our Lab Supplies range.

Microlisa HIV Ag & Ab 4th Generation ELISA Test Kit
Lab Supplies

Microlisa HIV Ag & Ab 4th Generation ELISA Test Kit

Blood screening exists in a category of laboratory work where the margin for error is not just professionally unacceptable but medically catastrophic. A false negative in HIV screening does not just fail a test. It compromises patient safety, undermines transfusion protocols, and exposes healthcare systems to risks that nobody wants to calculate. Microlisa HIV Ag & Ab 4th Generation ELISA was engineered to close the detection window that makes early HIV infection so difficult to identify reliably. This is an in-vitro qualitative enzyme immunoassay designed for simultaneous detection of antibodies to HIV-1 (including Group O and subtype C prevalent in India), HIV-2, and HIV-1 p24 antigen in human serum or plasma. The test is intended for screening of blood donors, diagnostic testing of individuals at risk for HIV infection, and clinical evaluation of patients with AIDS-related symptoms. It represents the fourth generation of HIV ELISA technology, which detects both antibodies and antigens simultaneously rather than antibodies alone. The clinical advantage of 4th generation testing is the shortened window period. Traditional antibody-only tests miss early seroconversion cases where HIV-1 p24 antigen is present but antibodies have not yet developed to detectable levels. By detecting p24 antigen during the acute infection phase (typically 2 to 4 weeks post-exposure), this assay identifies infections approximately 1 to 2 weeks earlier than 3rd generation antibody-only tests. That earlier detection matters critically in blood donor screening and post-exposure monitoring. The assay is based on sandwich ELISA methodology. Microtiter wells are pre-coated with HIV envelope proteins (gp41, C-terminus of gp120 for HIV-1, and gp36 for HIV-2) and anti-p24 monoclonal antibodies. When specimens are added, any HIV antibodies or p24 antigen present bind to the coated antigens or antibodies. After washing, horseradish peroxidase (HRPO) conjugated antigens and anti-p24 antibodies are added, forming a sandwich complex. The colorimetric reaction develops proportionally to the amount of HIV antibodies or antigen present, read at 450nm absorbance. The kit uses color-coded reagents to monitor procedural steps, reducing protocol errors during multi-step workflows. Breakaway microwell strips allow testing flexibility from single specimens to full 96-well plate runs. Storage stability is maintained at 2-8°C with a shelf life of 24 months unopened. Total assay time including incubation steps is approximately 120 minutes. Sensitivity and specificity meet international standards for 4th generation HIV screening. Clinical evaluations demonstrate 100% sensitivity in detecting seroconversion panels and p24 antigen standards quantified down to 200 pg/ml. Specificity exceeds 99.5% when tested against large sample populations. The test detects all major HIV-1 subtypes including Group O and subtype C, which are epidemiologically significant in the Indian subcontinent. For distributors supplying blood banks, transfusion centers, diagnostic laboratories, and public health screening programs, Microlisa HIV Ag & Ab represents a clinically validated 4th generation screening platform with predictable reorder cycles. Sara Wellness has been exporting in-vitro diagnostic kits and laboratory reagents from India for 15 years.

Advantage PAN Malaria Card Rapid Diagnostic Test Kit
Lab Supplies

Advantage PAN Malaria Card Rapid Diagnostic Test Kit

Malaria diagnosis in endemic regions operates under time pressure that microscopy cannot always accommodate. A patient presenting with fever in a rural health center at midnight does not have the luxury of waiting until morning for a trained microscopist to arrive, prepare slides, and spend twenty minutes examining blood films under oil immersion. That delay can mean the difference between timely artemisinin treatment and cerebral malaria developing overnight. Advantage PAN Malaria Card was designed to deliver species-level diagnosis in settings where microscopy is impractical or unavailable. This is a rapid visual immunoassay for qualitative detection of all four human Plasmodium species (P. falciparum, P. vivax, P. malariae, P. ovale) based on pan-specific plasmodium lactate dehydrogenase (pLDH) antigen in whole blood. The test provides results within 20 minutes using a simple fingerstick blood sample, no laboratory equipment required, making it ideal for point-of-care testing in primary health centers, rural clinics, field hospitals, and outbreak response settings. The assay is based on sandwich immunochromatography using monoclonal antibodies specific to pLDH, an enzyme produced by all Plasmodium species during their erythrocytic life cycle. When infected blood is added to the test device and assay buffer is applied, red blood cells lyse and pLDH antigen (if present) binds to gold-conjugated anti-pLDH antibodies. This complex migrates along the nitrocellulose membrane and is captured by immobilized anti-pLDH antibodies at the test line, producing a visible pink-purple band that confirms malaria infection. The see-through device design allows direct visualization of sample migration and result development, which helps identify invalid tests caused by insufficient sample volume or improper application. This transparency reduces the ambiguity that plagues some lateral flow devices where internal workings are hidden. Sensitivity and specificity have been validated through WHO malaria RDT evaluation programs using panels of wild and cultured parasites. The test detects parasitemia levels above 100 parasites per microliter of blood for both P. falciparum and P. vivax, which is clinically relevant for symptomatic infections requiring treatment. Specificity exceeds 99% when tested against cross-reactive conditions including dengue, leptospirosis, typhoid, and other febrile illnesses common in malaria-endemic areas. Shelf life is 24 to 30 months when stored at 4-30°C, which is critical for stockpiling in tropical climates where cold chain infrastructure is unreliable. The extended temperature stability means the test remains functional even when stored at ambient temperatures in resource-limited settings. Each kit contains individually sealed test devices, buffer vials, blood collection pipettes, and instructions for use. The test requires no special training beyond basic clinical skills and can be performed by nurses, paramedics, or trained community health workers. For distributors supplying national malaria control programs, public health departments, NGO field operations, and private diagnostic laboratories, Advantage PAN Malaria Card represents a WHO-evaluated rapid diagnostic platform with predictable consumption tied to malaria case loads. Sara Wellness has been exporting rapid diagnostic test kits and laboratory reagents from India for 15 years.

Human Serum Coombs Antisera (Antihuman Globulin Reagent)
Lab Supplies

Human Serum Coombs Antisera (Antihuman Globulin Reagent)

Blood banking operates on a fundamental requirement that most people never think about until something goes wrong. Every unit of blood transfused must be confirmed compatible with the recipient's immune system. Every pregnant woman screened for antibodies that could harm her unborn child. Every suspected case of hemolytic anemia investigated for antibodies attacking the patient's own red blood cells. None of this happens without Coombs antisera making the invisible antibodies visible. Human Serum Coombs Antisera is the reagent that makes antiglobulin testing possible in blood banks and immunohematology laboratories worldwide. This is antihuman globulin (AHG) reagent used in both direct and indirect antiglobulin tests (Coombs tests) to detect antibodies and complement components bound to red blood cell surfaces or present free in serum. The reagent is produced by immunizing animals (typically rabbits) with human immunoglobulins, which induces production of polyclonal antibodies specific for human IgG antibodies and complement factor C3d. When added to washed red blood cells coated with IgG or complement, the antihuman antibodies bind to the human antibodies and form bridges between adjacent sensitized cells, causing visible agglutination. The direct antiglobulin test (DAT) detects antibodies or complement already bound to red blood cell surfaces in vivo. This test is critical for diagnosing autoimmune hemolytic anemia, investigating hemolytic transfusion reactions, and diagnosing hemolytic disease of the fetus and newborn. The indirect antiglobulin test (IAT) detects free antibodies circulating in serum or plasma. This test is essential for pre-transfusion antibody screening, crossmatching blood units for compatibility, and prenatal antibody screening in pregnant women. Polyspecific Coombs antisera (like the green-colored reagent shown) contains antibodies against both IgG and C3d complement, providing broad-spectrum detection. When the polyspecific reagent produces a positive result, monospecific antisera (anti-IgG alone or anti-C3d alone) are used for follow-up testing to characterize whether red cells are coated with IgG antibodies, complement, or both. This differentiation is clinically important because it helps determine the cause and clinical significance of the positive test. The reagent is typically dyed green using patent blue and tartrazine to allow easy visual identification during laboratory workflows where multiple reagents are used simultaneously. Storage at 2-8°C maintains reagent potency until the expiration date printed on the bottle, typically 18 to 24 months from manufacture. The reagent contains sodium azide (0.1% w/v) as a preservative, which inhibits bacterial growth but requires careful handling and disposal. Each dropper bottle delivers approximately 40 microliters per drop, allowing precise volumetric dosing during testing. The reagent must not be diluted and should not be used if turbid, as turbidity indicates bacterial contamination or protein aggregation that will compromise test performance. For distributors supplying blood banks, hospital transfusion services, reference immunohematology laboratories, and donor screening centers, Coombs antisera represents an essential reagent with consumption directly tied to transfusion volume and prenatal screening programs. Sara Wellness has been exporting immunohematology reagents and blood banking supplies from India for 15 years.