Hitachi Sample Cups 500 Pack
Lab Supplies

Hitachi Sample Cups 500 Pack

Pack Sizes Available

Pack of 500 cups
Pack of 1000 cups (bulk)

Product Description

Chemistry analyser consumables are where laboratory efficiency quietly lives or dies. The analyser is visible. The sample cups, the reagents, the tubes, these flow through the laboratory invisibly until they don't. A delayed reagent shipment or an incompatible cup specification brings the workflow to a halt in ways that are immediately and expensively noticed. Hitachi sample cups are precision-manufactured polystyrene or polypropylene cups designed for use in Hitachi automated clinical chemistry analysers. These cups serve as the primary sample vessel from which the analyser aspirates patient serum or plasma for analysis. The cup geometry, material, and optical properties are specified by Hitachi to ensure compatibility with the aspirating probe dimensions, the cup identification system (where applicable), and the analyser's cup-handling mechanism. The 500-cup pack format reflects typical laboratory throughput for mid-volume chemistry labs that run 200-500 tests per day. The cups are individually designed with a flat base for stable positioning in the analyser tray, a precisely dimensioned inner diameter for accurate probe insertion depth, and materials that do not interact with the chemical reagents in the analysis. For laboratory supply managers, hospital procurement teams, and diagnostic network supply coordinators, Hitachi sample cups are a category where substitution with generic cups carries real analytical risk. Probe damage, liquid level sensing errors, and aspiration failures are documented consequences of cup-analyser incompatibility. Sara Wellness has been exporting laboratory consumables and analyser accessories from India for 15 years. We supply buyers across Africa, Southeast Asia, and the Middle East with compatible laboratory consumables at competitive institutional pricing.

Technical Specifications

  • Application: Sample vessel for Hitachi automated clinical chemistry analysers
  • Material: Optical-grade polystyrene or polypropylene
  • Pack Size: 500 cups per pack; 1000 cups per bulk pack
  • Sample Type: Serum and plasma (clinical chemistry applications)
  • Compatibility: Hitachi clinical chemistry analyser series (model-specific; confirm compatibility)
  • Use: Single-use disposable; do not reuse
FAQ

Frequently asked questions

Hitachi sample cups are used as the primary sample vessel in Hitachi automated clinical chemistry analysers. Patient serum or plasma is pipetted into the cup, which is then loaded into the analyser carousel or tray. The analyser aspirates the sample from the cup using a precision probe to perform biochemistry tests such as liver function, renal function, lipid profile, electrolytes, and other chemistry panels.

Hitachi sample cups are specifically dimensioned for Hitachi analyser models. While some cup specifications may be physically compatible with non-Hitachi analysers by coincidence, using cups in an analyser they were not designed for risks probe damage, aspiration failures, and liquid level detection errors. Always use the cup type specified by the analyser manufacturer for each specific model.

Hitachi sample cups are typically manufactured from optical-grade polystyrene or polypropylene, both of which are chemically compatible with the aqueous serum and plasma samples used in clinical chemistry. The material is chosen to minimize non-specific adsorption of analytes to the cup wall, which could cause sample carry-over or analytical interference in sensitive low-concentration assays.

No. Hitachi sample cups are single-use consumables. Reuse risks carry-over contamination between patient samples, which can cause false positive or false negative results in sensitive assays. After the analyser completes analysis of a sample, the cup is automatically discarded by the analyser mechanism or manually removed and disposed of as laboratory waste.

The minimum sample volume depends on the specific Hitachi analyser model and the tests being run. For most clinical chemistry panels on Hitachi analysers, the minimum sample volume required per cup is typically 100-250 µL of serum or plasma. The specific volume requirements should be confirmed in the analyser operating manual for the specific model in use.

Hitachi sample cups should be stored in a clean, dry environment at room temperature, protected from direct sunlight, moisture, and chemical vapors. They should be kept in their original packaging until use. Cups that have been exposed to high humidity or chemical vapors should not be used as this can affect their optical properties and chemical compatibility.

You might also like

Related Products

Explore more high-quality items from our Lab Supplies range.

Microlisa HIV Ag & Ab 4th Generation ELISA Test Kit
Lab Supplies

Microlisa HIV Ag & Ab 4th Generation ELISA Test Kit

Blood screening exists in a category of laboratory work where the margin for error is not just professionally unacceptable but medically catastrophic. A false negative in HIV screening does not just fail a test. It compromises patient safety, undermines transfusion protocols, and exposes healthcare systems to risks that nobody wants to calculate. Microlisa HIV Ag & Ab 4th Generation ELISA was engineered to close the detection window that makes early HIV infection so difficult to identify reliably. This is an in-vitro qualitative enzyme immunoassay designed for simultaneous detection of antibodies to HIV-1 (including Group O and subtype C prevalent in India), HIV-2, and HIV-1 p24 antigen in human serum or plasma. The test is intended for screening of blood donors, diagnostic testing of individuals at risk for HIV infection, and clinical evaluation of patients with AIDS-related symptoms. It represents the fourth generation of HIV ELISA technology, which detects both antibodies and antigens simultaneously rather than antibodies alone. The clinical advantage of 4th generation testing is the shortened window period. Traditional antibody-only tests miss early seroconversion cases where HIV-1 p24 antigen is present but antibodies have not yet developed to detectable levels. By detecting p24 antigen during the acute infection phase (typically 2 to 4 weeks post-exposure), this assay identifies infections approximately 1 to 2 weeks earlier than 3rd generation antibody-only tests. That earlier detection matters critically in blood donor screening and post-exposure monitoring. The assay is based on sandwich ELISA methodology. Microtiter wells are pre-coated with HIV envelope proteins (gp41, C-terminus of gp120 for HIV-1, and gp36 for HIV-2) and anti-p24 monoclonal antibodies. When specimens are added, any HIV antibodies or p24 antigen present bind to the coated antigens or antibodies. After washing, horseradish peroxidase (HRPO) conjugated antigens and anti-p24 antibodies are added, forming a sandwich complex. The colorimetric reaction develops proportionally to the amount of HIV antibodies or antigen present, read at 450nm absorbance. The kit uses color-coded reagents to monitor procedural steps, reducing protocol errors during multi-step workflows. Breakaway microwell strips allow testing flexibility from single specimens to full 96-well plate runs. Storage stability is maintained at 2-8°C with a shelf life of 24 months unopened. Total assay time including incubation steps is approximately 120 minutes. Sensitivity and specificity meet international standards for 4th generation HIV screening. Clinical evaluations demonstrate 100% sensitivity in detecting seroconversion panels and p24 antigen standards quantified down to 200 pg/ml. Specificity exceeds 99.5% when tested against large sample populations. The test detects all major HIV-1 subtypes including Group O and subtype C, which are epidemiologically significant in the Indian subcontinent. For distributors supplying blood banks, transfusion centers, diagnostic laboratories, and public health screening programs, Microlisa HIV Ag & Ab represents a clinically validated 4th generation screening platform with predictable reorder cycles. Sara Wellness has been exporting in-vitro diagnostic kits and laboratory reagents from India for 15 years.

Advantage PAN Malaria Card Rapid Diagnostic Test Kit
Lab Supplies

Advantage PAN Malaria Card Rapid Diagnostic Test Kit

Malaria diagnosis in endemic regions operates under time pressure that microscopy cannot always accommodate. A patient presenting with fever in a rural health center at midnight does not have the luxury of waiting until morning for a trained microscopist to arrive, prepare slides, and spend twenty minutes examining blood films under oil immersion. That delay can mean the difference between timely artemisinin treatment and cerebral malaria developing overnight. Advantage PAN Malaria Card was designed to deliver species-level diagnosis in settings where microscopy is impractical or unavailable. This is a rapid visual immunoassay for qualitative detection of all four human Plasmodium species (P. falciparum, P. vivax, P. malariae, P. ovale) based on pan-specific plasmodium lactate dehydrogenase (pLDH) antigen in whole blood. The test provides results within 20 minutes using a simple fingerstick blood sample, no laboratory equipment required, making it ideal for point-of-care testing in primary health centers, rural clinics, field hospitals, and outbreak response settings. The assay is based on sandwich immunochromatography using monoclonal antibodies specific to pLDH, an enzyme produced by all Plasmodium species during their erythrocytic life cycle. When infected blood is added to the test device and assay buffer is applied, red blood cells lyse and pLDH antigen (if present) binds to gold-conjugated anti-pLDH antibodies. This complex migrates along the nitrocellulose membrane and is captured by immobilized anti-pLDH antibodies at the test line, producing a visible pink-purple band that confirms malaria infection. The see-through device design allows direct visualization of sample migration and result development, which helps identify invalid tests caused by insufficient sample volume or improper application. This transparency reduces the ambiguity that plagues some lateral flow devices where internal workings are hidden. Sensitivity and specificity have been validated through WHO malaria RDT evaluation programs using panels of wild and cultured parasites. The test detects parasitemia levels above 100 parasites per microliter of blood for both P. falciparum and P. vivax, which is clinically relevant for symptomatic infections requiring treatment. Specificity exceeds 99% when tested against cross-reactive conditions including dengue, leptospirosis, typhoid, and other febrile illnesses common in malaria-endemic areas. Shelf life is 24 to 30 months when stored at 4-30°C, which is critical for stockpiling in tropical climates where cold chain infrastructure is unreliable. The extended temperature stability means the test remains functional even when stored at ambient temperatures in resource-limited settings. Each kit contains individually sealed test devices, buffer vials, blood collection pipettes, and instructions for use. The test requires no special training beyond basic clinical skills and can be performed by nurses, paramedics, or trained community health workers. For distributors supplying national malaria control programs, public health departments, NGO field operations, and private diagnostic laboratories, Advantage PAN Malaria Card represents a WHO-evaluated rapid diagnostic platform with predictable consumption tied to malaria case loads. Sara Wellness has been exporting rapid diagnostic test kits and laboratory reagents from India for 15 years.

Human Serum Coombs Antisera (Antihuman Globulin Reagent)
Lab Supplies

Human Serum Coombs Antisera (Antihuman Globulin Reagent)

Blood banking operates on a fundamental requirement that most people never think about until something goes wrong. Every unit of blood transfused must be confirmed compatible with the recipient's immune system. Every pregnant woman screened for antibodies that could harm her unborn child. Every suspected case of hemolytic anemia investigated for antibodies attacking the patient's own red blood cells. None of this happens without Coombs antisera making the invisible antibodies visible. Human Serum Coombs Antisera is the reagent that makes antiglobulin testing possible in blood banks and immunohematology laboratories worldwide. This is antihuman globulin (AHG) reagent used in both direct and indirect antiglobulin tests (Coombs tests) to detect antibodies and complement components bound to red blood cell surfaces or present free in serum. The reagent is produced by immunizing animals (typically rabbits) with human immunoglobulins, which induces production of polyclonal antibodies specific for human IgG antibodies and complement factor C3d. When added to washed red blood cells coated with IgG or complement, the antihuman antibodies bind to the human antibodies and form bridges between adjacent sensitized cells, causing visible agglutination. The direct antiglobulin test (DAT) detects antibodies or complement already bound to red blood cell surfaces in vivo. This test is critical for diagnosing autoimmune hemolytic anemia, investigating hemolytic transfusion reactions, and diagnosing hemolytic disease of the fetus and newborn. The indirect antiglobulin test (IAT) detects free antibodies circulating in serum or plasma. This test is essential for pre-transfusion antibody screening, crossmatching blood units for compatibility, and prenatal antibody screening in pregnant women. Polyspecific Coombs antisera (like the green-colored reagent shown) contains antibodies against both IgG and C3d complement, providing broad-spectrum detection. When the polyspecific reagent produces a positive result, monospecific antisera (anti-IgG alone or anti-C3d alone) are used for follow-up testing to characterize whether red cells are coated with IgG antibodies, complement, or both. This differentiation is clinically important because it helps determine the cause and clinical significance of the positive test. The reagent is typically dyed green using patent blue and tartrazine to allow easy visual identification during laboratory workflows where multiple reagents are used simultaneously. Storage at 2-8°C maintains reagent potency until the expiration date printed on the bottle, typically 18 to 24 months from manufacture. The reagent contains sodium azide (0.1% w/v) as a preservative, which inhibits bacterial growth but requires careful handling and disposal. Each dropper bottle delivers approximately 40 microliters per drop, allowing precise volumetric dosing during testing. The reagent must not be diluted and should not be used if turbid, as turbidity indicates bacterial contamination or protein aggregation that will compromise test performance. For distributors supplying blood banks, hospital transfusion services, reference immunohematology laboratories, and donor screening centers, Coombs antisera represents an essential reagent with consumption directly tied to transfusion volume and prenatal screening programs. Sara Wellness has been exporting immunohematology reagents and blood banking supplies from India for 15 years.